0 Your Cart 0,00 €

You have no items in your shopping cart.

-16%

ACTOCLEAN PERFECT ACTOCLEAN PERFECT

Enzymatic cleaner for endoscopes and medical instruments

Sku: 02.1016.1
14,99 €
17,99 €
Quantity:
+
-
  • Contains 4 enzymes (amylase, lipase, protease, cellulase)
  • For cleaning instruments and endoscopes
  • A concentrated product
  • Phosphate free
  • High material compatibility, Biodegradable in nature, and Suitable for manual use and ultrasonic washing machine

Produktbeschreibung

Actoclean ® Perfect is an enzyme-based concentrate cleaner for the manual cleaning of flexible endoscopes and surgical instruments. The instruments should be freed from organic contamination by pre-cleaning in order to increase the disinfection effect. The optimally coordinated 4-enzyme system offers excellent cleaning performance before sterilization or high-level disinfection. It effectively removes certain types of contaminants such as dried and stubborn blood, even in hard-to-reach places. In addition to the cleaning effect, Actoclean ® Perfect is gentle on instrument surfaces due to its special formula.

Chemical composition

100 g contains: 10 g non-ionic surfactants, 0.8 g benzalkonium chloride, 1 g enzyme mixture (protease, lipase, cellulase, amylase), corrosion inhibitors and auxiliary substances.

Concentration to use

concentration Amount of water Product quantity
% 0.5 1000ml 5ml
% 1 1000ml 10ml

Instructions for use

Put on suitable protective clothing before use. Actoclean ® Perfect is a concentrate that must be prepared in the desired concentration. Depending on the degree of contamination, prepare the prescribed amount of concentrate with water (temperature 15°C – 45°C) using a dosing pump. Depending on the contamination, the mixing ratio of concentrate and water can be varied. Dismantle instruments/endoscopes after use and place in the working solution (recommended usage concentration: 1%, which is 10 ml of concentrate in 990 ml of water) for approx. 15 minutes. Make sure that all surfaces and cavities are wetted. Depending on the level of contamination, mechanical cleaning by brushing may be necessary. Rinse cleaned instruments thoroughly with water and dry. Visually check instruments for cleanliness and repeat the process if necessary. Do not store instruments in the solution for longer than the recommended exposure time; the aqueous solution can cause long-term corrosion on sensitive instruments and devices. The working solution is intended for single use. After 24 hours, the unused working solution must be renewed.

Packaging

Unit Quantity in box Article no.
1 L 14 01.1016.1
5L 4 01.1016.5

Documents

Just added to your wishlist:
My Wishlist
You've just added this product to the cart:
Go to cart page